Seamless N08028 Incoloy Tube

Incoloy 028 Seamless Tube

UNS N08028 | 1.4563 | ASTM B668
Acid coolers, chemical exchangers and evaporators in aggressive process media place exacting demands on tube material, and Alloy 28 (UNS N08028) was designed precisely for such environments. As a high-alloy austenitic nickel-iron-chromium grade with molybdenum and copper, its chemistry targets acid streams where corrosion performance depends strongly on concentration and process contaminants. In wet-process phosphoric acid service, impurities can materially affect corrosion, so concentration alone is an incomplete basis for selection; the acid concentration, impurity profile and maximum metal temperature should all be provided for evaluation. Supply of the Incoloy 028 seamless tube is offered to ASTM B668. For equipment fabrication, confirm the outside diameter, wall basis, length and surface condition required by the drawing, along with any inspection records needed for acceptance. Where tube ends are welded into tubesheets, specify the fit and tolerances required by the design. Request a quotation with EN 10204 3.1 MTC today.
Quantity:
Contact Now

At a glance — Incoloy 028 Tube

SpecificationASTM B668 — the edition cited on the PO governs
Ordering basisOD × wall × length, wall basis stated (minimum or average)
Sourcing rangeOD 6 – 257 mm · wall 0.5 – 35 mm · length ≤ 18 m; each standard × OD × wall × length × condition confirmed in writing
ConditionSolution annealed; pickled & passivated, bright annealed or polished
DocumentsEN 10204 3.1 MTC as standard (3.2 on request); hydrostatic or NDT electric test on every length

Sourcing capability, not a stock list — availability, MOQ and lead time are stated in the written quotation.

Sizes, Wall Basis and Ordering

Two figures are kept apart here: the overall sourcing range — what we can supply ex-stock or source mill-direct — and the confirmed combination for your order (standard × OD × wall × length × manufacturing condition). The tables state the first; the written quotation fixes the second.

Supply combinations by outside diameter

OD band, mmWall range, mmSupply route (ex-stock / mill-direct)Order status
≤ 250.5 – 3.0Cold-drawn / cold-pilgeredIn stock · 3–7 days / mill-direct · 25–35 days
> 25 – 600.8 – 6.0Cold-drawnIn stock · 3–7 days / mill-direct · 25–35 days
> 60 – 114.31.5 – 10.0Cold-drawn; hot-finished above 8 mm wallIn stock · 3–7 days / mill-direct · 25–35 days
> 114.3 – 219.12.5 – 20.0Hot-finished; cold-finished on requestIn stock · 3–7 days / mill-direct · 25–35 days
> 219.1 – 2574.0 – 35.0Hot-finished (extruded)In stock · 3–7 days / mill-direct · 25–35 days

Stock items are marked In stock; everything else is mill-direct with a stated lead time. Wall figures give the range that can be drawn or rolled for that OD band; the ordered wall is always stated with its basis. Above 225 mm OD the tabulated dimensional bands no longer apply and the basis is agreed in writing before the order is accepted.

Ordering options

ItemWhat can be ordered
Outside diameter6 – 257 mm — drawn to the ordered OD, not to NPS
Wall thickness0.5 – 35 mm — minimum or average basis, stated on the order
LengthRandom 5–7 m, fixed up to 18 m, or cut to length
EndsPlain, bevelled, or capped for export packing
SurfacePickled and passivated, bright annealed, or polished
Delivery conditionSolution annealed; hardness and grain size reported on request

Sizes at the edge of a band, and anything above 225 mm OD, are quoted after technical review. If your enquiry is written in NPS and schedule, the quotation will restate it as OD × wall so both sides work from the same numbers.

Ordering Standards: B668 vs B619

Nickel alloys are not covered by A213 or A312. Each alloy carries its own B-series specification, and the mechanical values are set per alloy — so the specification and edition must be stated on the enquiry, not inferred from the grade name. B668 is the primary specification for this product; B619 is the companion specification that is sometimes cited instead.

ItemASTM B668ASTM B619
ScopePrimary B-series specification for this alloy in the ordered formCompanion specification; confirm which one the purchase order cites
Ordering basisOD × wall × length for tube, NPS × schedule or OD × wall for pipeSame dimensional notation, different acceptance clauses
Chemical limitsPer the alloy table of the primary specificationMay differ; the order must name the standard and edition
TestingIntegrity test plus the mechanical tests the specification requiresSame intent, different sampling and frequency
DocumentsEN 10204 3.1 with heat-number traceability3.1 or 3.2 as ordered

B163 covers seamless tube for several nickel alloys; B161, B165, B167, B407, B423, B444 and B622 cover pipe and tube by alloy family. The certificate cites the standard named on the order — mixing them after the fact is not possible.

Chemical Composition (Incoloy 028 Heat-Analysis Limits)

Chemical composition, % by weight:

GradeCSiMnPSCrNiCuMoFe
Seamless Incoloy N0≤ 0.03≤ 1.00≤ 2.50≤ 0.03≤ 0.0326.00–28.0030.00–34.000.60–1.403.00–4.00Bal

Values are the heat-analysis limits of the specification named above. Product analysis on the finished tube or pipe may differ within the tolerances the standard permits, and the actual heat analysis is printed on the mill test certificate.

Mechanical Properties and Physical Data

Mechanical properties:

Tensile StrengthYield StrengthElongationHardness
≥ 580 MPa≥ 214 MPa≥ 40%70-90HRB

Tensile and yield values are specification minima at room temperature; hardness and grain size are reported when the purchase order asks for them. Design values at service temperature must be taken from the applicable code, not from this table.

Permissible Variations in Dimensions (B668)

Dimensional acceptance follows the tables of the B-series specification named above, with B829 as the general tolerances reference where the product standard is silent. The bands below are representative; the edition cited on the purchase order governs.

Outside diameter

Outside diameter, mmPermissible variation
≤ 25± 0.13 mm
> 25 – 50± 0.20 mm
> 50 – 100± 0.38 mm
> 100 – 200± 0.76 mm
>200± 0.5 % of OD

Variations apply to the individual measurement. For cold-drawn tube the ovality is included in the OD band, not added to it.

Wall thickness

ConditionPermissible variation
Cold-finished± 10 % of ordered wall
Hot-finished+ 22.5 % / − 0 % of ordered wall
Minimum wall orderedNo point below the ordered minimum

The wall basis must match the design calculation; nickel-alloy tube is normally ordered on a minimum basis.

Fixed lengths: + 3 mm / − 0 mm. Random lengths 5–7 m unless a fixed length is ordered; straightness 1 in 600, and end squareness is inspected before packing.

Inspection, Testing and Mill Test Certificates

Three groups of evidence are separated here, because only the first is inside the base price. Anything in the second and third groups has to be written on the purchase order — it cannot be added after the mill test certificate has been issued.

GroupContentHow it is triggered
1 — IncludedChemical analysis, tensile test, flattening or bend test, hydrostatic or nondestructive electric test, dimensional check, EN 10204 3.1 certificateStandard supply; no extra instruction needed
2 — Written on the POUltrasonic or eddy-current testing to a stated acceptance level, PMI on each heat, intergranular corrosion test, grain size, hardness survey, 3.2 certificateMust appear on the purchase order; priced per order
3 — Third partyTPI witness (SGS, BV, TÜV, Lloyd's), destructive sampling, third-party laboratory, packing inspection, pre-shipment photographsArranged per order; extends the lead time

The test route is not interchangeable after the fact: if the certificate has to show ultrasonic testing, say so on the enquiry, because a hydrostatic-only pipe cannot be re-certified as ultrasonically tested.

What the mill test certificate records

Heat numberThe melt the item came from, traceable to the raw-material certificate
Grade and specificationGrade designation plus the standard and edition the order cites
Chemical analysisActual values for each element, not the range
Mechanical resultsTensile, yield, elongation and hardness as tested
Test routeHydrostatic or nondestructive electric test, plus any agreed NDT with the method reference
Heat treatmentSolution-annealing temperature range and cooling method
DimensionsOrdered OD, wall and length, with the measured values on request

Incoloy 028 Tube Applications and Points to Confirm

Each application below names the duty the grade is normally chosen for, and what should be settled before the order is placed — the third column decides whether this grade is the right one:

IndustryTypical duty
Chemical processingaggressive reaction and transfer duty
Pulp & papercooking liquor and bleaching duty
Fertilizerammonia, nitric and phosphoric duty
Marine & offshoresalt-laden marine duty
Water treatmentwater and wastewater duty
Petrochemical & refininghydrocarbon and sour-service duty

Points to confirm before ordering

  • Medium, concentration and chloride content — the figures that decide whether this grade holds
  • Design temperature and pressure, including upset and cleaning cycles
  • Whether the joint is welded, and the post-weld condition required
  • Inspection and document scope: NDT level, PMI, third-party witness

Send the medium, concentration, temperature, pressure and chloride level, and we will confirm the grade — or propose the next one up if the margin is narrow.

Grade Selection: Incoloy 028 vs TP904L

PropertyIncoloy 028TP904L
PREN, typical3834
Molybdenum3.00–4.004.00–5.00
Yield strength, min.≥ 220 MPa≥ 220 MPa
Service temperature≈ 400 °C≈ 400 °C
Choose whenThe acid, alkali or temperature exceeds what stainless steels holdLower alloy content is enough for the duty

PREN is indicative only and is calculated from the composition ranges above — it is not an acceptance value. Where the duty sits between two grades, the deciding factors are usually chloride content, temperature and whether the joint is welded.

Frequently Asked Questions

What sizes can be supplied in Incoloy 028 tube?

The overall sourcing range is OD 6 – 257 mm, wall 0.5 – 35 mm, length 18 m. The band table shows the wall range normally held or supplied for each OD band; the exact combination of standard, OD, wall, length and manufacturing condition is confirmed in the quotation. Sizes at the edge of a band are quoted after technical review.

Is this page a stock list?

In part. Stocked sizes are marked In stock and ship in 3–7 days; everything else is mill-direct with a 25–35 day lead time, confirmed per item in the quote.

Should the wall be ordered minimum or average?

Either, but it must be stated. A213-type tube is normally ordered on a minimum-wall basis, which is what the tolerance table in the dimensional section assumes. If your design code calls for average wall, say so on the enquiry and the quotation changes basis.

Which specification applies — B668 or B619?

ASTM B668 is the primary specification for this tube and the one the page describes. ASTM B619 is the adjacent specification; whether it applies depends on the ordered form, the test regime and the design code. State the standard and edition on the enquiry and the certificate will cite the same one.

Which tests and documents are included?

Mandatory: one integrity test per length (hydrostatic or nondestructive electric), tensile test per lot, dimensional check and an EN 10204 3.1 mill test certificate. Optional and only when written on the order: ultrasonic or eddy-current testing to a stated level, PMI, intergranular corrosion test, grain size, third-party witness and 3.2 certification.

How does Incoloy 028 compare with TP904L?

TP904L is the usual comparison grade. Incoloy 028 carries PREN of about 38 against 34 for TP904L, with a minimum yield of 220 MPa. The change is normally made when the duty — chloride level, temperature or pressure — leaves TP904L without margin over the design life.

Request an Incoloy 028 Tube Quotation

Send: specification and edition, OD or NPS, wall and wall basis, length, quantity, surface finish, inspection scope and documents, and destination port. The quotation will restate the confirmed size combination, delivery condition, documents included and lead time for Incoloy 028 Tube.

Request an Incoloy 028 Tube quotation

Related Product Forms and Grades

Other forms and neighbouring grades, each with its own specification — confirm the applicable standard on every order:

Technical data compiled from the ASTM/ASME specification tables cited above and from published mill data. Page reviewed by the Xinzhe technical team, 09–11-2026. All values must be confirmed against the edition current at the time of order and against the heat certificate.